Home Technique Fire Hose

Fire Hose



Introduction

Model: Φ65 8 type rubber lined hose; type 13 Φ65, Φ80 rubber lined hose; 16 Φ65-type rubber lined hose.

Management

Category

fire hose into lined fire hose and fire hose leakage categories. Fire hose lining fire hose comprising a rubber, TPU fire hose, polyester filling with glue, linen plastic hose. According to work under pressure into 0.8MPa, 1.0MPa, 1.3MPa, 1.6MPa four categories. 50,65,80 or 75, 90 divided by the diameter of four millimeters. Divided by plain weave and twill with water hose types. Saving the length of each band is generally defined as 20 m. .

Maintenance

① management hoses. To implement service management, according to quality classification, and record numbers, to grasp with water quality and use. Establish and improve the water system with maintenance, regular education full voluntary compliance.

② storage aspects. Should be specially designed storage sites or storage chamber, long-term storage of spare hose to select the proper temperature, ventilated place to store the water with a single layer of rolled legislation should turn on the water with a rack, turning twice a year or once exchange hem. Truck with water to avoid friction with each other, if necessary, be exchanged hemming.

③ use of. Laying should avoid sudden turns, twisting, after filling the water to avoid the drag force on the ground, avoiding contact with the oil, acid, alkali and other corrosive chemicals; may be in the region of strong flame or radiant heat, should be cotton or linen water tape; water with a hook to ascend when the laying of water; should be passed through by the railroad tracks from below, through the road, should be fitted with water for the bridge; when the water stop preventing angular contact with hard objects, buildings ripper, do not bring water to the polishing wood, steel and other items; hose should be cleaned after use; cold areas laying of water should be used lining hose outside the building.

④ repair aspects. When using a vulnerability is discovered, it should be wrapped with a cloth, so as not to expand the hole and put a mark, after a timely repair. Usually should always check and found that damage, timely repair.

using

fire hose with water cloth attachment, hook hose, hose for the bridge, an interface, and the like trap.

① hose cloth for wrapping the leaky fire hose, is one of the necessary accessories on the truck. A canvas and metal clamps and other parts.

② water are suspended with a hook tool fire hose, in fire fighting, during vertical laying of water higher ground water hose with a hook hung on the ladder or other object, would relieve with the force of falling water, and easy to manipulate gunner water gun fire exit water. Water with a hook by a canvas belt, metal hook, half-rings.

③ hose for the bridge for laying the protective hose cross pedestrian traffic, it does not affect the normal running of the vehicle equipment, having a high strength, durable compression, clean and convenient.

④ more types of interfaces, the interface with water, teeth of the interface, Reducing interface, shaped, a threaded interface or the like. A hose and hose, hydrant, fire pump is connected, water guns and other spray device. Press the button structure can be divided, and threaded insert other.

⑤ trap use, one stream of water in order to separate the two strands over two strands or flow; the second is used as a switch, by means of trap can be turned on or off from the hose line water, the water pump does not need to perform switching, thereby shortening the time required for opening and closing the water flow, to ensure timely supply fire. Trap trap has two, three quarters water and water is three.

test rules

1, when tested in the same species, the same diameter, length of 1000 m with a water batch. From a random selection of 100 meters do visual inspection. In the most economical method of three samples taken, sample length should meet the requirements of paragraph 3.1.1.

2, the inner diameter specimens shall comply with this standard; weight per unit length of three samples and the arithmetic average of seepage should conform to this standard; one sample only one state the burst test and shall comply with the provisions of this standard.

3, when an inspection does not meet this standard if the provisions that allow for the re-inspection once. When the re-inspection is still the most economical way to extract doubling the sample. The results of the retest specimens shall comply with the provisions of this standard, otherwise unqualified.

4, when the supply and demand sides of a dispute over the quality of products, all costs of the arbitration inspection borne by the responsible party.

maintenance measures

use and maintenance of the fire hose:

First, hose connections, the fire hose jacket when Sheung with connection shall be a single layer of flexible protective material, and then fastened with galvanized wire or hose clamps.

Second, the use of hoses. When using the fire hose, should be connected with high pressure water from the pump in place close to, the water-filled hose should prevent sudden twisting or bending, while the interface water stop should prevent collision damage.

Fire Hose

Third, water tape laying. When laying hose, to avoid sharp objects and folders various oils, higher ground when the vertical laying of water, when to use water with a hook, the laying of water through roads, should be fitted with water for the bridge, by rail when, following the track by the hose should avoid bad wheel was crushed with water intermittently supply.

Fourth, to prevent freezing. Winter season, when the court to suspend the fire water supply, water stop for the anti-icing, slow-running pumps need to keep a small amount of water.

Fifth, washed with water, with the water used to clean, the foam of the conveying hose, must careful washing, the protective rubber layer. Bring water to remove grease, use warm water to wash or soap, to freeze the hose, the first to use it to melt, then dry cleaning, no dry with no water storage volume accounts.

Note

Fire Hose Fire is a site with water hoses. Press materials can be divided into fire hose lining fire hose and unlined. Wherein linerless fire hose low pressure, high resistance, easy to leak, and easy to mold rot, short life, suitable for laying in a building fire; lining hose high pressure resistance, wear resistance, mold rot, durable durable, and difficult to leakage, small resistance, can be bent folded, free to move, easy to use, and is suitable for external fire laying oN fire .

Caution should fire hose:

1. Laying should avoid sudden turns, to prevent the reduction of the ability to withstand water pressure; should avoid twisting, to prevent rotation of the hose filled with water after the water with the button released interfaces.

2. After filling water to avoid drag force on the ground, to try to lift the moved position needs to be changed, to reduce wear and ground with water.

3. Should avoid contact with the oil, acid, alkali and other corrosive chemicals.

4. In a possible strong flame or radiant heat zone, should be cotton or linen with water.

5. After completion should be washed clean, the liner hose to hang drying, dry coil in a cool dry place.

6. Use of the process as they are damaged holes, apply water with a cloth bind tightly, as soon as possible after the darning or stick up; when there is visible damage, should immediately withdraw from combat.

7. When the vehicle needs by laying the hose, hose disposed in advance by site for the bridge.

8. For laying by rail, the following should be by rail.

9. Cold areas should be used outside of the building lined with water, bring water to avoid freezing.

fire hose attachment

is mainly water with an attachment means to connect and use the fire hose necessary accessories, including an interface, and the like trap.

1. Interface

is the interface with the water hose, fire pump, fire hydrant or mobile monitor linker. Interfaces mainly with water, teeth of the interface, bonnet, fixed interfaces internal thread, the external thread fixed interfaces, Reducing interface, profiled interface.

use should be noted:

(1) during use and storage, to avoid fall, hit the weight and prevent deformation of the assembly and disassembly difficult. Before

(2) is connected, and should be carefully checked sliding seal area, if sludge and grit and other debris should be promptly removed, to prevent difficulties and poor sealing of assembly and disassembly.

when the connector (3) button interface should be inserted into the chute and then screwed clockwise the claw feet. When connecting hose, with the need to straighten the water to the water with their own interfaces twisted disengaged. When

(4) connected to the interface plug-in, should be inserted into the female voice heard until the spring pin extending to the interface card slot interface to the male, in order to ensure reliable connection.

(5) avoid with acids, bases and other chemicals contacts, to prevent corrosion of metallic parts and rubber seals deterioration during storage.

2. Trap

water trap is connected to the water line separated branch flow appliance. By number of the divided leg, there are two trap, three quarters of the water and moisture.

(1) Structure

Each trap has a number of inlet and outlet, for use, respectively, may also be used, which are within the interface button . Are equipped on the outlet shutoff valve or ball valve may be closed at any time, flow control, and facilitate increasing branch exchange with water.

(2) use and maintenance

Before use, the interface to check the seals and valves are easy complete. Winter season to try to insulation to prevent freezing of failure. After a use clean water wash - clean.

How to buy

1, see the appearance certification

First, carefully review the appearance of fire protection products, to see if sophisticated, and see the production date and shelf life of products, at the same time, the nameplate products, test reports, the regular factory produced products of fire should have a "type approval certificate" a book report ", the national fire product conformity assessment Center issued "and the national fire Testing Center issued a" fire test compliance report ", and contrast" a book report on a "look and indicators are consistent with the purchase of fire protection products.

2, online confirmation

landing "China Fire Product Conformity Assessment Center" website, whether to check the purchase of fire protection products belonging to the record on the Website who has the record of products are generally for qualified products. And check "type approval certificate", "fire test compliance report" is true.

National Standard

National Standardization Management Commission Notice No. 23 of 2011, approved the release GB6246-2011 "fire hose", this standard is mandatory national standards, in 2012 since June 1 implementation. Since the implementation of the standard, the following three criteria abolished: GB6246-2001 "fire hose lining performance requirements and test methods"; GB4580-1984 "linerless fire hose"; GA34-1992 "wet fire hose technical conditions "

GB 6246-2011 predetermined performance requirements of the fire hose, test methods, inspection rules and signs, packaging, transportation, use and maintenance. Appearance quality standards for fire hose inner diameter, length, design pressure, the test pressure, the minimum burst pressure, wet with water seepage, mass per unit length, elongation, expansion coefficient, the twisting direction, bendability, adhesion , low temperature resistance, the liner (or cover layer) physical and mechanical properties made specific performance indicators, to fully assess the performance of the fire hose.

The main difference with the new standard GB 6246-2001 are as follows: (1) increase the fire hose model specifications and naming; (2) increases the performance requirements and test methods of wet fire hoses ; (3) Revision of the torsional performance requirements of the fire hose; (4) increase the abrasion resistance requirements fire hose and the corresponding test methods; (5) increase the required fire hose coupling properties and fire coupling test method; (6) increased use and maintenance of the fire hose.

This article is from the network, does not represent the position of this station. Please indicate the origin of reprint
TOP